Trane Furnace XR95 Diagnostic LED Code
Find Your Trane Furnace XR95 Diagnostic and error LED Code here.
Trane XR95 furnace provides a LED on its integrated furnace control for quick diagnostic. Here is its diagnostic code error codes:
Upflow/ Horizontal, Downflow/ Horizontal, Gas-Fired, Direct Vent Condensing Furnaces
*UH1B040A9241A
*UH1B060A9361A
*UH1B080A9421A
*UH1C080A9601A
* First letter may be “A” or “T”
*UH1C100A9481A
*UH1D100A9601A
*UH1D120A9601A
*DH1B040A9241A
*DH1B065A9421A
*DH1C085A9481A
*DH1D110A9601A
INTEGRATED FURNACE CONTROL ERROR FLASH CODES
Flashing Slow — Normal – No call for Heat Flashing Fast — Normal – Call for Heat Continuous ON — Replace IFC
Continuous OFF — Check Power
2 Flashes — System Lockout (Retries or Recycles exceeded) Draft Pressure Error – Possible problems:
Coding
Code
Macromedia flash player free download
Phones
Refrigerant
3 Flashes —
a) Venting problem
b) Pressure seitch problem c) Inducer problem
4 Flashes — Open High Limit Device
5 Flashes — Flame sensed when no flame should be present
6 Flashes — 115 Volt AC power reversed or Poor Grounding
7 Flashes — Gas valve circuit error
8 Flashes — Low flame sense signal
Check Ignitor circuit and Line “N” to 24VAC
9 Flashes —
“Common” voltage ( 2volts) (possibl grounding problem)
Trane Furnaces – Installation Manuals
Trane Furnaces – User Manuals SBE Electric Heating and Cooling Free Downloads
Find XB80 Service Facts for troubleshooting flow chart. Uploading Shortly
trane XR95 pressure switch error
Trane XR95 . … A red light is flashing on the control board. … the light is flashing 3 times which the sticker says is a pressure switch error
The post Trane Furnace XR95 Diagnostic LED Code appeared first on SBE Electric Heating and Cooling.